Belden 1069A 16/2P 600V Tray Cable BC Shielded TC-ER/NPLF PVCNYL/PVC Black

Belden

SKU:
1069A
$4.22/ft
Minimum Purchase:
1 ft
16 AWG tray cable with 2 pairs of PVC/nylon insulated stranded bare copper conductors, overall Beldfoil® shield, tinned copper drain wire, and a black PVC jacket. UL TC-ER/NPLF, 600V. View full description
$4.22/ft

Description

This 16 AWG 2 pair instrumentation cable is designed for industrial control and signal transmission in raceways, cable trays, and ducts. It features stranded bare copper conductors with PVC/Nylon insulation, an overall Beldfoil® shield with 100% coverage, a 16 AWG tinned copper drain wire, and a black PVC jacket. 

The Exposed Run (ER) rating on this cable means it meets crush and impact testing requirements, and is therefore tough enough to run outside a cable tray without additional protection, unlike standard tray cables which must be installed inside a conduit, raceway or other protection.

Applications

1069A is designed for use in industrial control, raceways, cable trays and ducts, digital control, instruments (4-20ma, 0-10v, ...),low voltage digital control (24v, …), encoders, control circuits, distributed control systems (DCS), programmable logic controllers (PLC), solenoids, valves, actuators and positioners.

Construction

  • 16 AWG stranded (7x24) bare copper conductors
  • 2 twisted pairs: ICEA Chart E1
  • Polyvinyl Chloride and Nylon (PVC-NYL) insulation 
  • Overall Beldfoil® shield (100% coverage)
  • 16 AWG (7x24) tinned copper drain wire 
  • Black Polyvinyl Chloride (PVC) jacket

Standards and Compliance

  • Environmental Suitability: Indoor/Outdoor, Sunlight Resistance, Burial
  • Flammability / Fire Resistance: UL1685 (FT4 Loading), FT4, IEEE 1202 FT4
  • NEC / UL Compliance: Article 336, Article 760, NPLF, TC-ER
  • European Directive Compliance: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE)
  • APAC Compliance: China RoHS II (GB/T 26572-2011)

Click here for the Belden 1069A Technical Data Sheet.

Specifications

Brand:
Belden
Conductor Size:
16 AWG
Conductor Count:
2 Pairs
Conductor Type:
Stranded
Conductor Material:
Bare Copper
Insulation:
PVC/NYL - Polyvinyl Chloride + Nylon
Shield:
Shielded
Jacket Material:
PVC - Polyvinyl Chloride
Color:
Black
Manufacturer:
Belden
Manufacturers item number:
1069A
CSA:
FT4
NEC:
TC/NLPF
Outside Diameter:
0.456 in
Voltage rating:
600V
Weight per Foot:
0.095 lb

Manufacturer Equivalents

Alpha Wire item:
M8706020
Belden item:
1069A 0107500
Omni Cable item:
BEL1069A
Wirexpress item:
2AS-1602POS-B
Omni item:
BEL1069A

Pro Wire & Cable is a Proud Supplier to US Gov't Agencies, Universities & Trusted Brands

UEID: FJKDJ5JSPAH7   CAGE: 8GZ43   DUNS: 114451316

Supplier to NASA
Supplier to Tesla