Description
At ProWireandCable.com, our vast assortment of high-quality fiber optic cables includes the MIC Unitized Tight-Buffered Cable, Riser, 48 Fiber, Single-Mode (OS2) (048E81-61131-24)!
Description
Corning Cable Systems MIC Unitized Riser Cables are designed for use in riser and general purpose environments for intrabuilding backbone installations. These multifiber cables use individually jacketed 900 µm TBII Buffered Fibers enabling easy, consistent stripping and facilitating termination. The six or 12-fiber subunits allow quick and easy identification and are surrounded by dielectric strength members and protected by a flame-retardant outer jacket.
The all-dielectric cable construction requires no grounding or bonding, making these cables ideal for routing inside buildings including riser shafts, to the telecommunications rooms and workstations. The MIC Unitized Riser Cables meet the application requirements of the National Electrical Code (NEC) Article 770 and the ICEA S-83-596 test criteria. They are OFNR and FT-4 listed.
This cable is available in 12 different jacket colors - blue, orange, green, brown, slate, white, red, black, yellow, purple, rose and aqua. The colored jacket allows for easy visual identification of the cables.
Applications
General Purpose Horizontal, Vertical Riser
Specification Description
- Cable Type: Tight-Buffered
- Environment: Indoor
- Fiber Category: Single-mode (OS2)
- Flame Rating: Riser (OFNR)
- Product Type: Distribution
- Central Element: Jacketed GRP
- Fiber Count (cable): 48
- Fibers per Subunit: 6
- Number of Ripcords: 9
- Number of Subunits: 8
- Outer Jacket Color: Yellow
- Outer Jacket Material: Flame-retardant
- Subunit Central Element: Dielectric
- Subunit Color: Yellow
- Tensile Strength Elements and/or Armoring - Layer 1: Dielectric strength members
- Tight buffer color subunit: Blue, Orange, Green, Brown, Slate, White
- Max. Tensile Strengths, Long-Term (Metric): 400 N
- Max. Tensile Strengths, Long-Term (US): 90 lbf
- Max. Tensile Strengths, Short-Term (Metric): 1320 N
- Max. Tensile Strengths, Short-Term (US): 300 lbf
- Min. Bend Radius Installation (Metric): 267 mm
- Min. Bend Radius Installation (US): 10.5 in
- Min. Bend Radius Operation (Metric): 178 mm
- Min. Bend Radius Operation (US): 7 in
- Nominal Outer Diameter (Metric-mm): 17.8 mm
- Nominal Outer Diameter (US): 0.69 in
- Weight (cable) (Metric): 264 kg/km
- Weight (cable) (US): 177 lb/1000 ft
- Temperature - Installation (Metric): -10 C to 60 C
- Temperature - Installation (US): 14 F to 140 F
- Temperature - Operation (Metric): -20 C to 70 C
- Temperature - Operation (US): -4 F to 158 F
- Temperature - Storage (Metric): -40 C to 70 C
- Temperature - Storage (US): -40 F to 158 F
Tech Info
Approval and Listings: National Electrical Code (NEC) OFNR, CSA FT-4, ICEA S-83-596; Flame Resistance: UL-1666 (for riser and general building applications); Free of hazardous substances according to RoHS 2002/95/EG.
For more options, we ask you to take the occasion to shop our entire collection of fiber optic cables at ProWireandCable.com today.