Belden 1064A 18/4P 600V Tray Cable BC Shielded TC-ER/NPLF PVCNYL/PVC Black

Belden

SKU:
1064A
$4.05/ft
Minimum Purchase:
1 ft
18 AWG tray cable with 4 pairs of PVC/nylon insulated stranded bare copper conductors, overall Beldfoil®shield, tinned copper drain wire, and a black PVC jacket. UL TC-ER/NPLF, 600V. View full description
$4.05/ft

Description

This 18 AWG 4 pair extended run instrumentation cable is designed for industrial control and signal transmission in raceways, cable trays, and ducts. It features stranded bare copper conductors with PVC/Nylon insulation, an overall Beldfoil® shield with 100% coverage, an 18 AWG tinned copper drain wire, and a black PVC jacket.

The Exposed Run (ER) rating on this cable means it meets crush and impact testing requirements, and is therefore tough enough to run outside a cable tray without additional protection, unlike standard tray cables which must be installed inside a conduit, raceway or other protection.

Applications

1064A is designed for use in industrial control, raceways, cable trays and ducts, digital control, instruments (4-20ma, 0-10v, ...), low voltage digital control (24v, …), encoders, control circuits, distributed control systems (DCS), programmable logic controllers (PLC), solenoids, valves, actuators and positioners.

Construction

  • 18 AWG stranded (7x26) bare copper conductors
  • 4 pairs: ICEA Chart E1
  • Polyvinyl Chloride and Nylon (PVC-NYL) insulation 
  • Overall Beldfoil® Bi-Laminate (Alum+Poly) shield (100% coverage) 
  • 18 AWG stranded (7x26) tinned copper drain wire
  • Black Polyvinyl Chloride (PVC) jacket with ripcord

Standards and Compliance

  • Environmental Suitability: Indoor/Outdoor, Sunlight Resistance, Burial
  • Flammability / Fire Resistance: UL 1685 FT4 Loading, IEEE, 1202, FT4
  • NEC / UL Compliance: Article 336, Article 760, NPLF, TC-ER
  • European Directive Compliance: EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (ROHS II), EU Directive 2012/19/EU (WEEE)
  • APAC Compliance: China RoHS II (GB/T 26572-2011)

Click here for the Belden 1064A Technical Data Sheet.

Specifications

Brand:
Belden
Armored:
No
AWG:
18
Number of Conductors:
4 Pairs
Conductor type:
Stranded Bare Copper
Construction:
Overall Beldfoil® Shield
Insulation:
PVC/NYL - Polyvinyl Chloride + Nylon
Jacket type:
PVC - Polyvinyl Chloride
Manufacturer:
Belden
Manufacturers item number:
1064A 0107500
Shield:
Yes
Temperature:
90 C (194 F)
Thermocouple:
No
Voltage rating:
600V

Manufacturer Equivalents

Alpha Wire item:
M8708040
Anixter item:
2AS-1804POS-B
Belden item:
1064A 0107500
Wirexpress item:
2AS-1804POS-B
Omni Cable item:
BEL1064A