Type G and G-GC

(Showing 8 of 20)
  • SKU: 106623

    8/4C Type G 90C 2KV Black

    Four conductors of 8 AWG stranded bare copper, EPDM insulation, and a thermoset CPE jacket. UL Type G (Ground), 2KV. Suitable for heavy impact, severe conditions, and chemical/acids/heat exposure. Temp: 90C. Outer jacket: black.
    $8.91/ft
    Call for Same Day Shipping
  • SKU: 106622

    8/3C Type GGC 90C 2KV Black

    Three conductors of 8 AWG stranded bare copper, EPDM insulation, and a thermoset CPE jacket. UL Type GGC (Ground with Ground Check), 2KV. Suitable for heavy impact, severe conditions, and chemical/acids/heat exposure. Temp: 90C. Outer jacket: black.
    $5.78/ft
    Call for Same Day Shipping
  • SKU: 106621

    6/4C Type G 90C 2KV Black

    Four conductors of 6 AWG stranded bare copper, EPDM insulation, and a thermoset CPE jacket. UL Type G (Ground), 2KV. Suitable for heavy impact, severe conditions, and chemical/acids/heat exposure. Temp: 90C. Outer jacket: black.
    $11.73/ft
    Call for Same Day Shipping
  • SKU: 106619

    4/4C Type G 90C 2KV Black

    Four conductors of 4 AWG stranded bare copper, EPDM insulation, and a thermoset CPE jacket. UL Type G (Ground), 2KV. Suitable for heavy impact, severe conditions, and chemical/acids/heat exposure. Temp: 90C. Outer jacket: black.
    $18.00/ft
    Call for Same Day Shipping
  • SKU: 106618

    4/3C Type GGC 90C 2KV Black

    Three conductors of 4 AWG stranded bare copper, EPDM insulation, and a thermoset CPE jacket. UL Type GGC (Ground with Ground Check), 2KV. Suitable for heavy impact, severe conditions, and chemical/acids/heat exposure. Temp: 90C. Outer jacket: black.
    $9.93/ft
    Call for Same Day Shipping
  • SKU: 106617

    2/4C Type G 90C 2KV Black

    Four conductors of 2 AWG stranded bare copper, EPDM insulation, and a thermoset CPE jacket. UL Type G (Ground), 2KV. Suitable for heavy impact, severe conditions, and chemical/acids/heat exposure. Temp: 90C. Outer jacket: black.
  • SKU: 106616

    2/3C Type GGC 90C 2KV Black

    Three conductors of 2 AWG stranded bare copper, EPDM insulation, and a thermoset CPE jacket. UL Type GGC (Ground with Ground Check), 2KV. Suitable for heavy impact, severe conditions, and chemical/acids/heat exposure. Temp: 90C. Outer jacket: black.
    $13.34/ft
    Call for Same Day Shipping
  • SKU: 106615

    1/3C Type GGC 90C 2KV Black

    Three conductors of 1 AWG stranded bare copper, EPDM insulation, and a thermoset CPE jacket. UL Type GGC (Ground with Ground Check), 2KV. Suitable for heavy impact, severe conditions, and chemical/acids/heat exposure. Temp: 90C. Outer jacket: black.
    $17.05/ft
    Call for Same Day Shipping

Pro Wire & Cable is a Proud Supplier to US Gov't Agencies, Universities & Trusted Brands

UEID: FJKDJ5JSPAH7   CAGE: 8GZ43   DUNS: 114451316

Supplier to NASA
Supplier to Tesla